Air Cooled Chillers
Air Cooled & Water Cooled Chillers
Non-Refrigerated Heat Exchange Systems

Tek-Temp Instruments, Inc
401 Magnolia Ave.
Croydon, PA 19021
Tel: (215) 788-5528
Fax: (215) 788-7737
Toll-Free: 800-259-4212
chiller@tek-tempinstruments.com

Credit Cards

Model NRD-550

Liquid-to-Liquid Heat Exchange Systems

NRD-550 Liquid-to-Liquid Heat Exchange SystemsThe NRD-550 Series models are non-refrigerated heat exchange systems which utilize a tap or building water source to remove heat from your process. They are particularly useful in situations where the cooling water source temperature is too low, or where the pressure and cleanliness of the water may cause damage to the equipment or compromise performance. An internal plate-type heat exchanger is used to remove heat efficiently while isolating the cooling and process loops. Large quantities of heat can be removed in a small physical size as compared to refrigerated models. Our modular frames are used to package these systems in order to ensure the smallest possible footprint.

NRD-550 systems are equipped with digital temperature display, a coolant pressure gauge, a liquid level switch, and a flow/pressure adjustment valve. Heat removal capacities are dependent on the cooling water flow rate and on the process water flow rate. A variety of circulating pumps are available to match process requirements. Our engineers are happy to assist in selecting the proper circulating pump and heat exchange system.

Available Options: All stainless steel and polymeric wetted parts, flow meter, pressure relief valve, flow switch, dual level alarm.

Applications

Specifications

Specifications for: NRD550/S1 NRD550/S2 NRD550/S3 NRD550/S4
Cooling Capacity
(BTU/hr) @ 20°C
See Performance Charts Below
Temp. Control Range 5 to 38°C
Stability ± 0.5°C
Reservoir Volume (gallons) 2.5 8.0
Recirculating Capacity
(see Pump Curves)
T1 R3, T2C C150, T2B, T2D CB500
Power Requirements
(Volts, Ø, Hz)
115, 1, 60 115, 1, 60 115, 1, 60 208, 3, 60
Dimensions
W x H x D (inches)
19-5/8 x 33 x 24-5/8 22-3/8 x 36 x 27-5/8 36-1/2 x 38-5/8 x 28
Available Options Coolant filter, Flow adjustment valve, Flow meter, Flow switch, Pressure relief valve, All stainless steel and polymeric wetted parts, Temperature alarm

Available Options

All Stainless Steel and Polymeric Wetted Parts • Flow Meter • Pressure Relief Valve • Flow Switch • Dual Level Alarm.

Available circulating pumps are rated for continuous operation.
Performance specifications will be affected by changes in coolant temperature, ambient temperature, or type of coolant used.

Specifications may change without notice. Specifications can be customized.
Call our Engineering Department at 1-800-259-4212 for assistance.